How to calculate electromagnet holding force for real parts

  • Ideal pull at the pole face follows F = B²A/(2μ0), so doubling flux density gives four times the force.
  • Catalog holding force is measured at zero air gap on thick, flat, low-carbon steel, and real parts rarely match that.
  • Size the magnet from the load, a safety factor of 2-3 and a derating for gap, steel and coil heat.

Electromagnet holding force is calculated with the Maxwell pull equation, F = B²A/(2μ0), where B is flux density at the pole face and A is pole area in contact with the steel. At 1.0T over 10cm² of pole face, the ideal pull is about 398N. Real force is lower once air gaps, thin steel and coil heating are counted.

What formula gives electromagnet holding force?

The standard formula for electromagnet holding force is F = B²A/(2μ0). F is the force in newtons, B is the flux density at the contact face in tesla, A is the pole area touching the steel in square meters, and μ0 is the permeability of free space, 4π × 10-7H/m. The result is an ideal upper limit.

The equation comes from the energy stored in the magnetic field where the pole meets the steel. Force rises with the square of B. That is why a small loss of flux costs a lot of pull.

In round pot-style holding electromagnets, flux leaves the center pole, crosses into the steel part and returns through the outer ring. Both faces pull, so A is the center pole area plus the ring area.

Cross-section of a round holding electromagnet on a steel plate, with flux flowing from the center pole back via the outer ring
Flux leaves the center pole, crosses the plate and returns through the outer ring

Worked example in SI units

StepValueNote
Flux density at the pole face, B1.0TA common design value, below saturation of low-carbon steel
Total pole area in contact, A1,000mm² = 1.0 × 10-3m²Center pole plus outer ring
Permeability of free space, μ04π × 10-7 = 1.2566 × 10-6H/mPhysical constant
Denominator, 2μ02.5133 × 10-6H/m–
Force, F = B²A/(2μ0)(1.0² × 1.0 × 10-3) ÷ (2.5133 × 10-6) = 397.9NAbout 40.6kgf or 89.4lbf
Ideal pull, zero air gap, uniform flux and no leakage

So a face with 10cm² of active pole area, run at 1.0T, can pull about 398N in perfect contact, and the same face pushed to 1.5T would reach roughly 895N, because 1.5² is 2.25.

Flux density BMagnetic pressureIdeal force on 10cm² of pole
0.5T9.9N/cm²99N
0.8T25.5N/cm²255N
1.0T39.8N/cm²398N
1.2T57.3N/cm²573N
1.5T89.5N/cm²895N
Calculated from F = B²A/(2μ0); real magnets deliver less

Flux density cannot climb forever. Low-carbon steel starts to saturate above roughly 1.5T and tops out near 2T, and past that point extra coil current mostly adds heat rather than pull.

Why is rated holding force measured at zero air gap?

Rated holding force is measured under best-case conditions so that different electromagnets can be compared fairly. The usual set is rated DC voltage, a flat ground plate of low-carbon steel thick enough not to saturate, full pole coverage, zero air gap and a pull straight off the face. Few production parts match all five, and catalogs do not all use the same set: a review of how 12 catalogs state holding force ratings found warm and cold conventions side by side.

Treat the catalog figure as a ceiling. The product tables for our DC holding electromagnet range state the test conditions under each table, so you can see which of these assumptions your part breaks.

New Lodegrip holding electromagnet designs go through in-house type tests for holding force against steel thickness, coil temperature rise and life. Until those results are published on this page, the derating figures below are general engineering guidance, not Lodegrip measurements.

Hands holding a steel plate on a rectangular holding electromagnet powered from a 24V DC bench supply
Checking a holding electromagnet against steel plate on a DC bench supply

How much does an air gap reduce holding force?

An air gap reduces holding force faster than most buyers expect, because steel carries flux hundreds to thousands of times more easily than air. Paint, plating, rust, dirt, a curved face or a plastic film all behave as a gap. A single coat of paint, around 0.1mm, can remove a quarter or more of the rated force.

In simple magnetic-circuit terms, once the gap g dominates, B ≈ μ0NI/(2g) for a pot magnet, because the flux crosses the gap twice. N is the number of turns and I is the coil current.

Force then falls roughly with the inverse square of the gap. Small magnets have fewer ampere-turns and narrower poles, so the same gap takes a larger share of their force.

Air gapTypical causeTypical remaining force
0mmGround steel, clean and flat100% (rated)
0.05mmLight oil film, fine dust, thin tape75-95%
0.1mmOne coat of paint, light rust55-85%
0.2mmThick paint, mill scale40-70%
0.5mmPowder coat, plastic film, shim15-45%
1.0mmRough casting, bent sheet5-25%
Typical engineering guidance for small and mid-size holding electromagnets, not test results

Ranges are wide because the loss depends on pole size and coil design. Small magnets sit at the low end of each range. Confirm with a sample on your own part. Standard zinc or nickel plating is usually 5 to 12 microns thick, well below the first gap row.

Illustrative chart of holding force against air gap from 0 to 1mm, with the small magnet curve falling faster than the large
Illustrative curves drawn from the ranges in the table above

Why does thin steel hold less?

Thin steel holds less because it cannot carry all the flux the magnet produces. Once the sheet saturates, the extra flux leaks into the air and the pull drops, even with perfect contact. The thickness needed for full force depends on pole size, so large magnets need thicker steel than small ones.

A quick estimate works for a round magnet. Flux leaving a center pole of diameter d has to turn sideways through the sheet to reach the outer ring, and the sheet cross-section at the pole edge is πd × t.

Setting that equal to the pole area πd²/4 gives a minimum thickness of about t ≈ d/4.

By that rule, a 20mm center pole needs about 5mm of low-carbon steel to reach its rated force. For a rectangular magnet with a center pole strip of width w and flux returning on both sides, the same logic gives t ≈ w/2.

The table below applies that rule to a generic example: a 50mm round holding electromagnet rated about 600N at 24V and 100% ED. Its center pole is about 25mm across, so the knee falls near 6mm. Below that, force drops steeply with every millimeter of sheet.

Illustrative chart of holding force rising with steel thickness and leveling off near t = d/4, later for large poles
Illustrative: full force needs steel about a quarter of the pole diameter thick
Steel thickness (S235)Estimated holding force (N)Share of rating
1mmAbout 40About 7%
2mmAbout 100About 17%
3mmAbout 200About 33%
4mmAbout 350About 58%
5mmAbout 450About 75%
6mmAbout 550About 92%
8mmAbout 600100%
10mmAbout 600100%
15mmAbout 600100%
Rounded estimates for a generic 50mm round electromagnet at 24V, 100% ED, zero air gap, ground surface; from the saturation model, not test results

Above about 8mm the plate carries all the flux, so extra thickness adds nothing. Smaller magnets reach full force on thinner steel.

Thin sheet is the reason electromagnetic grippers for sheet handling use several narrow poles instead of one large pole. Narrow poles close the flux loop over a short distance, which keeps it inside a thin sheet.

Which steels hold well, and which barely hold?

Low-carbon steels such as 1010, 1018 and Q235 hold best, because they combine high permeability with high saturation. Medium-carbon steel, hardened tool steel and cast iron hold less. Ferritic and martensitic stainless grades hold with reduced force, and austenitic stainless such as 304 or 316 hardly holds at all.

Part materialTypical force vs low-carbon steel
Low-carbon steel (1010, 1018, Q235)100% (reference)
Medium-carbon steel (1045)80-95%
Hardened or alloy tool steel50-80%
Gray cast iron45-70%
Ferritic or martensitic stainless (430, 410)40-70%
Austenitic stainless (304, 316)Near 0%; cold-worked areas may attract slightly
Aluminum, copper, brass0%
Typical engineering guidance at the same thickness and contact; not test results

Coatings follow the same logic. Zinc, chrome and paint are not magnetic, so they count as air gap whatever the steel underneath.

Do surface finish and contact area matter?

Surface finish and contact area both matter, because the formula only counts pole area in true contact. A ground face touches almost everywhere, while a milled, sawn or cast face touches at its high points and leaves micro-gaps. A part that covers only half the pole face, or misses the center pole, loses about half its force or more.

Flatness counts too. A slightly bowed sheet may sit on the outer ring and float over the center pole, which breaks the flux loop and can cut the pull sharply. Pick a magnet whose face the part covers completely, even if that means a smaller magnet.

How do coil temperature and supply voltage change force?

A DC holding electromagnet draws current I = V/R, and copper resistance rises about 0.39% per °C. When a coil warms from 20°C to 80°C, its resistance rises about 24%, so current falls to roughly 81% of the cold value. Low supply voltage has the same effect. Both reduce flux, and force follows flux squared.

In a gap-dominated circuit, 81% of the current gives about 65% of the force, since 0.81² is about 0.65. At zero gap on thick steel the iron runs closer to saturation, so the loss is smaller.

A 24V supply that sags to 21.6V cuts current by 10% and gap-limited force by up to 19%.

Duty cycle sets how hot the coil gets. A coil rated for 100% duty cycle can stay on continuously, while one rated lower needs off time between holds or it will run past the limit of its insulation class. Size for the hot coil when the magnet holds for long periods.

What safety factor should you use?

A common engineering rule is a safety factor of at least 2 on a static load pulled straight off the face, and 3 or more when the part moves, vibrates or is carried by a robot. Apply the factor after derating for gap, steel and temperature, and never hold a load over people with an electromagnet alone.

Required force for a straight pull is F = m × (g + a) × S, where m is the part mass, g is 9.81m/s², a is the upward acceleration and S is the safety factor.

If the load slides along the face instead (shear), divide by the friction coefficient μ. Magnet makers commonly assume μ of only 0.15-0.25, because oil and plating make the surface slippery.

Case (5kg steel blank, robot accelerating at 5m/s², S = 2)CalculationRequired force
Straight pull off the face5 × (9.81 + 5) × 2148.1N
Shear along a vertical face, μ = 0.25 × (9.81 + 5) × 2 ÷ 0.2740.5N
Straight pull, painted part (0.7 from the gap table)148.1 ÷ 0.7About 212N rated
Worked sizing example; thickness and heat losses would raise the rated force further

The shear case needs five times the force of the straight pull, so where possible mount the magnet so that the load pulls straight off the face, or add a mechanical stop to take the sliding load.

An energize-to-hold magnet also drops its load when the power fails. If that would be dangerous, add a mechanical catch or a backup supply, and read our electromagnet vs permanent magnet comparison before you choose.

How do you specify a holding electromagnet in an RFQ?

Specify a holding electromagnet by describing the part and the job, not only a force number. Give the part material, thickness, surface and weight, the direction of pull, how fast it moves, the supply voltage, the duty cycle and the ambient temperature. With that data a supplier can size the coil and pole geometry properly.

  • Part: steel grade, thickness at the contact point, coating and surface finish, flatness and contact area.
  • Load: weight, straight pull or shear, acceleration and the safety factor you want.
  • Electrical: 12V or 24V DC (or another voltage), duty cycle, power limit, lead wire length and connector.
  • Environment: ambient temperature, IP rating, oil or coolant exposure.
  • Mechanical: maximum envelope, mounting thread, release time and any residual magnetism limit.
  • Order: quantity and target sample date.

Lodegrip parts come from a Foshan, China, factory that has made electromagnets since 1992, and we quote from that list with orders from 50 pieces, samples in seven days and production in about 25 days. The factory is ISO 9001 certified, uses RoHS compliant materials and applies CE marking where the product falls under it.

Every line above is unpacked, with an example of what to write on each one, in our electromagnet RFQ checklist for buyers.

Holding force FAQ

Is holding force the same as lifting capacity?

No. Holding force is the pull-off force under ideal test conditions. Lifting capacity must also allow for air gap, steel thickness, motion and a safety factor, so it is usually well under half the rated holding force.

Does a bigger magnet always hold more?

Only when the part is thick enough and covers the whole face. On thin sheet a large pole saturates the steel, so a smaller magnet or a multi-pole design can hold as well or better.

Why does the part stick after the power is off?

Residual magnetism in the core and the part leaves a small pull. Spring-loaded ejector pins, a thin non-magnetic shim or a short reverse-polarity pulse from the controller will release light parts cleanly.

Can I raise the force by raising the voltage?

It depends on the gap. Across an air gap, force rises roughly with the square of the current, but at zero gap on thick steel the iron is near saturation and gains little. Higher voltage also raises coil heat, so running above the rated voltage shortens coil life unless the magnet was designed for short over-excitation.

How do I convert newtons to kilograms of force?

Divide by 9.81. A 398N holding force equals about 40.6kgf, or about 89.4lbf.

Need a second check on your force margin?

Send the part drawing, weight and supply voltage. An engineer will check the margin and suggest a size, or you can send your electromagnet sizing request with the RFQ list above.

Foshan factory since 1992 · ISO 9001 certified factory · MOQ 50 pcs · samples in seven days

More electromagnet guides

  • How to test electromagnet holding force so the result means something

    To test electromagnet holding force, clamp a flat, ground steel plate to the energized pole face, pull it straight off slowly with a force gauge, and record the peak force. Repeat at least three times, and note the plate grade and thickness, surface, air gap, terminal voltage and whether the coil was cold or warm.

  • Electromagnet shear force: holding parts on vertical faces and moving robots

    Electromagnet shear force is the sideways load a holding electromagnet can resist before the part slides along its pole face. It comes only from friction, so it is typically a fifth or less of the rated pull. Parts on vertical faces and parts moved quickly by robots load the magnet in shear.

  • Why electromagnet holding force ratings don’t compare across catalogs

    An electromagnet holding force rating is a pull measured under conditions each maker chooses: test steel, plate thickness, surface, voltage and coil temperature. In 12 public catalogs those conditions differed, and most left some out. Two ratings can only be compared after checking that both were taken under the same conditions.