Engineering guides for electromagnet buyers
These guides help engineers and buyers specify DC holding electromagnets with fewer surprises. They explain how holding force is calculated, why real parts hold less than the catalog rating, and when an electromagnet beats a permanent magnet. Each guide states the assumptions behind its numbers, so you can check them against your own application.
Specifying and quoting a custom electromagnet
- How to size a 24V power supply for DC holding electromagnets
To size a power supply for DC holding electromagnets, add up the cold-coil current of every magnet that can be energized at the same time, then add about 25% margin and allow for the cabinet temperature. Then size the cable so each magnet still sees at least 95% of its rated voltage with all of them on.
- Incoming inspection for holding electromagnets: what to check and how many
Incoming inspection for holding electromagnets checks a delivered batch against the agreed specification before it reaches the line. A practical plan covers appearance and pole face condition, dimensions and mounting, leads and connector, coil resistance corrected to 20°C, insulation, and a holding force test on a smaller sample, all under conditions agreed beforehand.
- What a supplier needs to quote your holding electromagnet
A supplier needs 14 details to quote a holding electromagnet or a linear solenoid: what the part is made of, how hard the coil has to work, the supply and control, the space and mounting, the environment, and the order. Send all 14 and one reply replaces a week of questions.
Holding force and magnet sizing
- How to test electromagnet holding force so the result means something
To test electromagnet holding force, clamp a flat, ground steel plate to the energized pole face, pull it straight off slowly with a force gauge, and record the peak force. Repeat at least three times, and note the plate grade and thickness, surface, air gap, terminal voltage and whether the coil was cold or warm.
- Electromagnet shear force: holding parts on vertical faces and moving robots
Electromagnet shear force is the sideways load a holding electromagnet can resist before the part slides along its pole face. It comes only from friction, so it is typically a fifth or less of the rated pull. Parts on vertical faces and parts moved quickly by robots load the magnet in shear.
- Why electromagnet holding force ratings don’t compare across catalogs
An electromagnet holding force rating is a pull measured under conditions each maker chooses: test steel, plate thickness, surface, voltage and coil temperature. In 12 public catalogs those conditions differed, and most left some out. Two ratings can only be compared after checking that both were taken under the same conditions.
- How to calculate electromagnet holding force for real parts
The Maxwell pull formula with a worked SI example, then the losses from air gap, thin steel, material, surface and coil heat, and a safety-factor rule for sizing.
Troubleshooting and maintenance
- Why a holding electromagnet loses force, and how to find the cause on the line
A holding electromagnet that clamps weaker than it used to has not worn out magnetically, because it holds no magnetism while switched off. The loss comes from something that changed: lower voltage at the coil, a damaged or hot winding, a worn or dirty pole face, a larger air gap, or a different part.
- Why a holding electromagnet runs hot, and when it is too hot
A DC holding electromagnet gets hot because its coil turns its full rated power into heat for as long as it holds. That is normal. It is too hot when the winding nears its insulation limit, usually from high supply voltage, longer holds than its duty rating, a mounting that traps heat, or hot parts.
- Why a holding electromagnet still grips after the power is off
A DC holding electromagnet that still grips after the coil is switched off has one of three problems: current is still flowing in the coil, the faces are stuck by film or binding, or residual magnetism is left in the steel. Each one has a different fix.
Robot grippers and sheet handling
- How to size an electromagnetic gripper for a robot
Sizing an electromagnetic gripper for a robot means turning the part, the move and the robot into a force, a magnet layout and a weight. Start from the heaviest part, its surface and the peak acceleration, apply a safety factor that suits the move, then spread enough magnets to match how stiff the part is.
- Electromagnetic or vacuum gripper for sheet metal: how to choose
An electromagnetic gripper holds steel by passing magnetic flux through the part, while a vacuum gripper holds any sealed, smooth surface by suction. For steel sheet with holes, oil, embossing or rough edges, the electromagnet is usually the more reliable choice. For aluminum, stainless or non-metal parts, vacuum is the only one that works.
Push-pull solenoid selection
- Sizing a push-pull solenoid return spring against the force curve
A push-pull solenoid return spring has to sit inside a window. At the open position it must push harder than friction and any weight it lifts, or the plunger will not come back. At every point of the stroke it must stay below the coil force, or the plunger will not pull in.
- Push-pull solenoid not pulling in? Six checks before you replace it
A DC push-pull solenoid that will not pull in fully is almost always short of force where its stroke begins, where the coil is weakest. Check the voltage at the terminals during the stroke, the coil and driver ratings, the load and spring at the open position, friction, and coil temperature, in that order.
- DC solenoid duty cycle explained: what it does to coil temperature
The duty cycle of a DC solenoid is the share of each cycle its coil is energized, and it exists to cap coil temperature. Power while on turns into heat. Off time lets it escape. The rating is the longest on share that keeps the winding under its insulation class limit at the stated ambient temperature.
- Push-pull solenoid sticking or slow to return? Find the cause first
A push-pull solenoid that sticks or returns slowly has one of two problems: something drags on the plunger, or something keeps pulling it after the power goes off. Remove power and load, then push the plunger by hand. If it drags, fix friction and alignment. If it slides freely, check the spring and the coil circuit.
- Choosing a push-pull solenoid: settle these six specs first
Choosing a push-pull solenoid means settling six specifications in order: stroke, force at that stroke, duty cycle, voltage at the terminals, mounting and side load, then life and environment. Each answer narrows the next. Work down the list and the body size, the coil and the price follow from it.
- Reading a solenoid force-stroke curve before you order
A solenoid force-stroke curve plots the force a DC linear actuator produces at every plunger position, from fully extended to seated against the pole piece. Force rises steeply as the gap closes. Size the unit at the position where your load starts to resist, never at the catalog peak.
- Push or pull: choosing the action of a DC linear solenoid
A DC linear solenoid draws its plunger into the coil whenever the coil is powered. Pull action uses that travel directly. Push action turns it around with a pin through the pole piece. Your machine motion, the return method and the mounting decide which one to order.
Electromagnet principles and comparisons
- Electromagnets or permanent magnets: which one should hold your part?
A side-by-side table covering control, power-loss behavior, energy, heat and residual magnetism, plus when each type is the right choice.

DC holding electromagnets by shape
Ready to pick a model? Round, rectangular and gripper designs in 12V and 24V DC, built to order from 50 pieces.
Need help sizing a part?
Send the part, the load and your supply voltage through our RFQ form with drawing upload, and an engineer replies with a suggested size.