- Pull is the native build. Push action is the same inward travel sent back out through a pin.
- The force curve belongs to the plunger, not to the action, so both are weakest at full stroke.
- Return method, mounting and duty cycle decide the specification more often than the word push or pull does.
A DC linear solenoid draws its plunger into the coil whenever the coil is powered. Pull action uses that travel directly. Push action turns it around with a pin through the pole piece. Your machine motion, the return method and the mounting decide which one to order.
What do push and pull action mean at the plunger?
Pull action brings the load toward the body: the plunger closes the gap to the pole piece and drags whatever is fastened to its shaft. Push action sends a pin the other way through that pole piece, so the same inward travel drives a rod out of the far end.
Catalogs often call the part a plunger actuator, after the moving steel core that does the work. One machine therefore sees two different motions from one magnetic event. That is the whole trick, and it explains why a catalog can list the same body under both names. Our custom tubular push-pull solenoids are built either way from the same tube, coil and plunger, with the plunger end machined to suit your linkage.
| Question | Pull action | Push action |
|---|---|---|
| What leaves the body | A shaft on the armature side | A pin through the pole piece |
| Where the load sits | Behind the solenoid, pulled in | In front of the nose, pushed out |
| Typical job | Pulling a latch, tensioning a lever, closing a clamp | Ejecting a part, lifting a stop, setting a pawl |
| Bearing points | One, inside the tube | Two, once the pin is guided |
Does the force-stroke curve change with the action?
Magnetically, no. Both actions come from the same plunger travel, so the curve rises as the gap closes and is weakest at full stroke. What changes is mechanical loss. A push pin adds a guided length outside the tube, and a little of the rated force goes into friction and alignment before the load moves at all.
Read the curve at the position where your load actually resists, not at the closed position where the catalog figure is measured. Our guide to reading a solenoid force-stroke curve works through that step. Published tubular data also links the plunger end to the useful stroke range: flat ends favor short travel of roughly 3mm and under, and conical ends spread the force over medium travel of a few millimeters more.
Standard bodies in our range run from under 15mm to about 90mm in diameter with strokes up to about 35mm, and open frame bodies reach about 25mm. Force-stroke, temperature rise and life are all covered by in-house solenoid type tests when a new design is released.
What brings the plunger back: spring, gravity or the mechanism?
Nothing returns on its own. A return spring is the usual answer and sits inside the body or on the output shaft. Gravity works when the axis is vertical and the moving mass is honest about it. A lever, a cam or a spring already in the machine can also do the job, as long as it acts every cycle.
Whatever returns the plunger has to be paid for twice. Its force subtracts from the magnetic force during pull-in, which matters most at full stroke where the coil is weakest, and it has to beat friction on the way back. Push layouts make this sharper, because the pin can take dirt, heat or paint from the process side.
Say in the enquiry which direction is the powered one and which is the fail direction. A part that must stay clear when the line stops needs the spring pushing it clear, not the coil holding it clear.
How do mounting and side load decide the layout?
Mount the body so the plunger travels along its own axis and nothing tugs it sideways. Side load presses the plunger against its bearing surface, which costs force, wears the bore and can stall a long stroke. Published service guidance treats misalignment as a leading cause of early solenoid failure.
Push layouts feel this first. The pin works as a slender column reaching past the bearing, so an off-axis load bends it rather than the plunger. If the linkage cannot be aligned, guide the pin in its own bush, or turn the problem around and let the mechanism pull instead.

Tubular bodies mount by a threaded nose and nut or by tapped holes in the end face; frame bodies bolt flat. Mounting style, stroke and plunger end are made to order, so it is cheaper to fix alignment on the drawing than in the machine.
What happens if the solenoid holds at the end of stroke?
Holding is a thermal question, not a force question. Duty cycle sets how much power the coil can take, and power sets force. A body rated at 10% ED gives roughly a third of that peak when it runs continuously and about 60% at 25% ED, which are engineering estimates from the catalog ratings rather than test results.
So a mechanism that has to stay latched all shift is a 100% ED job, and it should be sized on the continuous figure. Coils are wound on a bobbin with Class B insulation, and running past the rated duty cycle takes the winding past that limit whatever the body shape.
The duty cycle ratings behind those factors assume rated voltage, a coil starting at 20°C, a cycle time of five minutes or less and no side load. They are catalog and estimated values for standard designs, not measurements from your unit. A long hold at the closed position is also the case where a driver that drops to a lower holding voltage earns its place.
How do you turn a machine motion into a solenoid spec?
Describe the motion before naming a product. What moves, how far, against what resistance, in which direction, and how often per minute. Then convert that into stroke in millimeters, the force needed at the far end of the stroke, the on and off times, and the supply voltage available at the terminals.
Five answers settle most enquiries: stroke, force at that stroke, push or pull, duty cycle, and the space envelope. Add the plunger end you need, the lead length and whether the unit sees dust or splashes. A sketch of the linkage answers three of those at once and usually corrects one of them.
Leave margin. Supply voltage sags under load, a warm coil resists more than a cold one, and the load you measured on the bench is the lightest it will ever be. Sizing on the figure at your working position, rather than the headline peak, is what keeps a mechanism reliable on the second shift.
When is a holding electromagnet the better answer?
When the job is clamping rather than moving. A holding electromagnet has no stroke at all: it clamps a flat steel part against its pole face while powered and lets go when the current stops. If your mechanism only has to keep something in place, a solenoid stalled at the end of its travel is the wrong tool.
The two are often confused because both are DC coils in steel. The difference is what they do with the air gap. A solenoid closes it to make motion; a DC holding electromagnet for clamping starts with the gap closed and spends its whole duty holding it shut.
Sizing a clamp works differently too, since steel thickness, surface finish and the smallest air gap dominate the result. Start with calculating electromagnet holding force and compare the answer against what a stroke-based mechanism would cost you.
How we checked this
This guide draws on published industrial practice for DC linear solenoids, on standard catalog rating conditions for duty cycle and force, and on what this factory builds: tubular and open frame bodies, push or pull action, spring return, machined plunger ends and made-to-order mounting. The size bands and the duty cycle factors repeat the catalog ratings and estimates already published on our solenoid page. We did not measure force, stroke loss, pin friction or coil temperature for this article, so no number here is a Lodegrip test result. Written 19 September 2026.
Push and pull action FAQ
What is a pull solenoid?
A pull solenoid is a DC linear actuator whose shaft moves toward the body when the coil is powered, dragging the load in. On a drawing it shows as a shaft on the armature side with a thread or clevis, no push pin through the pole piece, and the stroke dimensioned from rest to the seated position.
Is a plunger solenoid actuator the same as a linear solenoid?
Yes, they are the same class of part. Plunger actuator names the moving steel core; linear solenoid names the straight-line travel. Both describe a coil that pulls a plunger over a fixed stroke and returns it by spring. Rotary and latching types behave differently, so state stroke and return in the enquiry.
Is a push solenoid weaker than a pull solenoid?
The magnetic force is the same, since both come from the same plunger travel. In the machine the push version can feel weaker, because the pin adds friction and any misalignment loads it sideways. Size on the force at your working stroke and that difference stays small.
Can one unit push and pull in the same machine?
Only in one direction at a time under power. A shaft can be fitted at both ends, so one end pulls a load in while the other pushes something out, but both motions happen on the same energized stroke. The return still has to come from a spring or the mechanism.
Do I need a return spring if the machine already springs back?
No, and leaving it out gives you the full magnetic force during the stroke. Check that the machine spring acts on every cycle, survives the same life as the coil and is easy to service, because it now carries the whole return job.
Where is the stroke measured from?
From the plunger position at rest to the closed position against the pole piece. That is why force is always quoted with a stroke figure: the same coil gives its lowest force at the start of travel and its highest just before the plunger seats.
Can the plunger end be machined to suit my linkage?
Yes. Thread, clevis, flat, pin diameter and shaft length are made to order, along with stroke, voltage, duty cycle rating and lead length. The usual terms apply: 50 pieces minimum, samples in about 10 to 12 days and production in about 25 days.
Not sure which way your mechanism should move?
Send the stroke, the force at that stroke, the on and off times and a sketch of the linkage. An engineer will propose a size and an action, and we will check your stroke and force against the curve before anything is built.
Foshan factory since 1992 · ISO 9001 certified factory · MOQ 50 pcs · samples in 10 to 12 days